+91 8617752708

American Chemical Science Journal, ISSN: 2249-0205,Vol.: 5, Issue.: 2

Original-research-article

A Sequential Injection Analysis Method for the Determination of Glyphosate and Aminomethylphosphonic Acid in Water Samples

 

Britta Jahnke1*, Carsten Frank1, José F. Fernández2 and Bernd Niemeyer1,2

1Institute of Coastal Research, Molecular Recognition and Separation, Helmholtz-Zentrum Geesthacht, Max-Planck-Straße 1, D-21502 Geesthacht, Germany.
2Institute of Thermodynamics, Helmut-Schmidt-University, University of the Federal Armed Forces Hamburg, Holstenhofweg 85, D-22043 Hamburg, Germany.

Article Information
Editor(s):
(1) Nagatoshi Nishiwaki, School of Environmental Science and Engineering, Kochi University of Technology Tosayamada, Kami, Kochi 782-8502, Japan.
Reviewers:
(1) Anonymous, Jiaxing University, China.
(2) Anonymous, Universidade Estadual do Centro-Oeste do Paraná, Brazil.
(3) Anonymous, University of São Paulo, Brazil.
Complete Peer review History: http://www.sciencedomain.org/review-history/6828

Abstracts

A conventional laboratory method for the determination of glyphosate and its degradation product aminomethylphosphonic acid (AMPA) is high performance liquid chromatography (HPLC) followed by post column derivatization with o-phthaldialdehyde (OPA). However, AMPA is partly decomposed in the process causing a deviation in the AMPA detection or even making a simultaneous detection of glyphosate and AMPA with the described postcolumn procedure impossible. We used a compact sequential injection analysis system and optimized the process conditions for both analytes independently from each other. The process conditions were adjusted to the different chemical characteristics of AMPA (primary amine) and glyphosate (secondary amine), which needs to be oxidized to a primary amine prior to the derivatization. An ion exchange column was included in the system to eliminate amines interfering with the method. Limits of detection of 16 and 9 µg L-1 for glyphosate and AMPA, respectively are similar to those achieved with HPLC methods reported in literature, but compared to conventional HPLC methods only small amounts of reagents are consumed.

Keywords :

Glyphosate; roundup; AMPA; sequential injection analysis; SIA; phosphororganic analysis.

Full Article - PDF    Page 163-173

DOI : 10.9734/ACSJ/2015/13089

Review History    Comments

Our Contacts

Guest House Road, Street no - 1/6,
Hooghly, West Bengal,
India

+91 8617752708

 

Third Floor, 207 Regent Street
London, W1B 3HH,
UK

+44 20-3031-1429