+91 8617752708

Journal of Applied Life Sciences International, 2394-1103,Vol.: 15, Issue.: 1

Original-research-article

Novel Non-parametric Assessment of Heavy Metals in Coated Card Wastes

 

C. I. A. Nwoko1*, A. U. Nkwoada1, P. C. Njoku2 and A. Obichini1

1Department of Chemistry, Federal University of Technology Owerri, P.M.B. 1526, Nigeria.

2Department of Environmental Technology, Federal University of Technology Owerri, P.M.B. 1526, Nigeria.

Article Information
Editor(s):
(1) Vasil Simeonov, Laboratory of Chemometrics and Environmetrics, University of Sofia “St. Kliment Okhridski”, Bulgaria.
Reviewers:
(1) Hermine Ramzy Zaki Tadros, National Institute of Oceanography and Fisheries, Egypt.
(2) Dal Singh Kharat, India.
Complete Peer review History: http://www.sciencedomain.org/review-history/21827

Abstracts

Non-parametric tests were applied for the first time to coated mobile card waste in order to determine the correlation within risk assessment and instrumentation. The AAS concentrations of all the metals were higher than their XRF concentrations except in Al and Ag metals. Cr had the highest distribution pattern while Ag metal had the lowest respectively. The target hazard quotient (THQ) for all metals were below minor hazard level. On the contrary, only Fe and Zn were below the Oral reference dose (RfD) value and the daily metal intake (DMI) respectively. The Wilcoxon-Mann-Whitney test showed no significant difference between the concentration of the metals in XRF and AAS analysis results but identified the unusual behavior of Ag and Al metals; hence it depicted that both AAS and XRF analysis results were not sensitive to detect the different metal concentrations in the cards. Hence, similar coating specifications are utilized. The Kruskal Wallis test and Spearman correlation coefficient showed that the results from AAS and XRF were significantly different. Hence it showed that instrumentation showed sensitivity of metal concentrations from the recharge cards. This correlated with THQ, DMI, health risk index (HRI) risk assessment parameters that different coating specifications were used causing different values at same sampling points. Therefore, the results established that non-parametric tests are good analytical tools.

Keywords :

Non-parametric; card-waste; heavy-metals; risk-assessment.

Full Article - PDF    Page 1-10

DOI : 10.9734/JALSI/2017/37258

Review History    Comments

Our Contacts

Guest House Road, Street no - 1/6,
Hooghly, West Bengal,
India

+91 8617752708

 

Third Floor, 207 Regent Street
London, W1B 3HH,
UK

+44 20-3031-1429